Description
Model | Detail | Picture | |
KEL-2000 | For Upright Biological Microscope | 1. Power supply voltage: 220V±10%, AC45—60HZ
2. Output voltage: 36V, power: 50W 3. Temperature setting method: digital display, preset 4. Temperature control range: room temperature -60°C 5. Measurement accuracy: full range ≤±0.2°C 6. System working environment temperature: adaptive room temperature working temperature 7. Heating plate size: 150×125×8mm, aperture: 20×60mm |
|
KEL-2000A | For Inverted Biological Microscope | 1. Power supply voltage: 220V±10%, AC45—60HZ
2. Output voltage: 36V, power: 50W 3. Temperature setting method: digital display, preset 4. Temperature control range: room temperature -60°C 5. Measurement accuracy: full range ≤±0.2°C 6. System working environment temperature: adaptive room temperature working temperature 7. Table size: φ110/φ108mm |
|
KEL-2000B | For Stereo Microscope | 1. Power supply voltage: 220V±10%, AC45—60HZ
2. Output voltage: 36V, power: 50W 3. Temperature setting method: digital display, preset 4. Temperature control range: room temperature -60°C 5. Measurement accuracy: full range ≤±0.2°C 6. System working environment temperature: adaptive room temperature working temperature 7. Workbench size: 165×130×8mm, aperture: φ38mm |
|
KEL-2000C | For High Precision Sperm Microscope | 1. Power supply voltage: 220V±10%, AC45—60HZ
2. Output voltage: 36V, power: 50W 3. Temperature setting method: digital display, preset 4. Temperature control range: room temperature -60°C 5. Measurement accuracy: full range ≤±0.1°C 6. System working environment temperature: adaptive room temperature working temperature |
|
X-4 | Melting Point Detector | 1. Input power: AC 220V ±10% 45-60HZ
2. Temperature range: room temperature—300°C 3. Power consumption: 60W 4. The maximum temperature of the outer body of the heating stage: when the heating body is 300°C; when the room temperature is 25°C, it is ≤70°C 5. Accuracy: Measurement accuracy: full range ≤ ± 0.2% 6. System fluctuation: ±1°C 7. Specifications of heating stage: shape φ108mm×thickness 10.5mm Thermal body φ32mm×thickness 8.5mm Clear hole φ4.0mm, mass 215g 8. Instrument size: 176×160×108 (MM), mass 2.38kg |
|
X-4H | Melting Point Detector | 1. Input power: AC 220V ±10% 45-60HZ
2. Temperature range: room temperature—300°C 3. Power consumption: 60W 4. The maximum temperature of the outer body of the heating stage: when the heating body is 300°C; when the room temperature is 25°C, it is ≤70°C 5. Accuracy: Measurement accuracy: full range ≤ ± 0.2% 6. System fluctuation: ±1°C 7. Specifications of heating stage: shape φ108mm×thickness 10.5mm Thermal body φ32mm×thickness 8.5mm Clear hole φ4.0mm, mass 215g 8. Instrument size: 176×160×108 (MM), mass 2.38kg |
|
X-5 | Microscope precision thermostat Golden Terrace
|
1. Input power: AC 220V ±10% 45-60HZ
2. Temperature range: room temperature—450°C 3. Power consumption: 60W 4. The maximum temperature of the outer body of the heating stage: when the heating body is 360°C; when the room temperature is 25°C, it is ≤70°C 5. Accuracy: Measurement accuracy: full range ≤ ± 0.2% 6. System fluctuation: ±1°C 7. Specifications of heating stage: shape φ108mm×thickness 10.5mm Thermal body φ32mm×thickness 8.5mm Clear hole φ4.0mm, mass 215g |
|
KER3101-500S | For Polarization Microscope | 1. Input power: AC 220V ±10% 45-60HZ
2. Temperature range: room temperature—500°C 3. The range of heating/cooling speed can be set: 1-60 seconds/℃ (the heating and cooling are the same as the knob) 4. Temperature rise/fall control: automatic recognition conversion, one-twist setting. 5. The maximum temperature of the outer body of the heating stage: when the heating body is 500°C; when the room temperature is 25°C, it is ≤70°C 6. Accuracy: Measurement accuracy: full range ≤ ± 0.5% 7. System fluctuation: ±1°C 8. Immediate constant temperature response time: ≤0.01 seconds |
|
X-500S | Microscope precision thermostat Golden Terrace
|
1. Input power: AC 220V ±10% 45-60HZ
2. Temperature range: room temperature—500°C 3. Power consumption: 60W 4. The maximum temperature of the outer body of the heating stage: when the heating body is 360°C; when the room temperature is 25°C, it is ≤70°C 5. Accuracy: Measurement accuracy: full range ≤ ± 0.2% 6. System fluctuation: ±1°C 7. Specifications of heating stage: shape φ108mm×thickness 10.5mm Thermal body φ32mm×thickness 8.5mm Clear hole φ4.0mm, mass 215g 8. Instrument size: 176×160×108 (MM), mass 2.38kg |
|
KER5100 | High-precision two-way precision thermostat (hot and cold stage)
|
1. Temperature range of constant temperature table: minus 50°C. (The lowest temperature depends on the temperature of the heat exchange fluid. When the heat exchange flow is at room temperature of 18 °C, it can reach minus 30 °C.
2. Controller input power: AC 220V ±10% 45-60HZ. 3. Working power supply of constant temperature table: DC 0-12V 0-6A automatic adjustment. 4. Accuracy: Measurement accuracy: full range≦±0.2% 5. System fluctuation: ±0.1°C Display scale: 0.1°C 6. Rise/fall speed function: bidirectional linear. 7. The heating/cooling speed range can be set: 1-36 seconds/0.1 ℃, the same button setting, automatic conversion. 8. Immediate constant temperature response time: ≦0.1 seconds. 9. Heating/cooling status judgment: automatic. 10. Heating/cooling crossover out of control zone: ≦±1.5℃. |