KEL-2000 For Upright Biological Microscope 1. Power supply voltage: 220V±10%, AC45—60HZ

2. Output voltage: 36V, power: 50W

3. Temperature setting method: digital display, preset

4. Temperature control range: room temperature -60°C

5. Measurement accuracy: full range ≤±0.2°C

6. System working environment temperature: adaptive room temperature working temperature

7. Heating plate size: 150×125×8mm, aperture: 20×60mm

KEL-2000A For Inverted Biological Microscope 1. Power supply voltage: 220V±10%, AC45—60HZ

2. Output voltage: 36V, power: 50W

3. Temperature setting method: digital display, preset

4. Temperature control range: room temperature -60°C

5. Measurement accuracy: full range ≤±0.2°C

6. System working environment temperature: adaptive room temperature working temperature

7. Table size: φ110/φ108mm

KEL-2000B For Stereo Microscope 1. Power supply voltage: 220V±10%, AC45—60HZ

2. Output voltage: 36V, power: 50W

3. Temperature setting method: digital display, preset

4. Temperature control range: room temperature -60°C

5. Measurement accuracy: full range ≤±0.2°C

6. System working environment temperature: adaptive room temperature working temperature

7. Workbench size: 165×130×8mm, aperture: φ38mm

KEL-2000C For High Precision Sperm Microscope 1. Power supply voltage: 220V±10%, AC45—60HZ

2. Output voltage: 36V, power: 50W

3. Temperature setting method: digital display, preset

4. Temperature control range: room temperature -60°C

5. Measurement accuracy: full range ≤±0.1°C

6. System working environment temperature: adaptive room temperature working temperature

X-4 Melting Point Detector 1. Input power: AC 220V ±10% 45-60HZ

2. Temperature range: room temperature—300°C

3. Power consumption: 60W

4. The maximum temperature of the outer body of the heating stage: when the heating body is 300°C; when the room temperature is 25°C, it is ≤70°C

5. Accuracy: Measurement accuracy: full range ≤ ± 0.2%

6. System fluctuation: ±1°C

7. Specifications of heating stage: shape φ108mm×thickness 10.5mm

Thermal body φ32mm×thickness 8.5mm

Clear hole φ4.0mm, mass 215g

8. Instrument size: 176×160×108 (MM), mass 2.38kg

X-4H Melting Point Detector 1. Input power: AC 220V ±10% 45-60HZ

2. Temperature range: room temperature—300°C

3. Power consumption: 60W

4. The maximum temperature of the outer body of the heating stage: when the heating body is 300°C; when the room temperature is 25°C, it is ≤70°C

5. Accuracy: Measurement accuracy: full range ≤ ± 0.2%

6. System fluctuation: ±1°C

7. Specifications of heating stage: shape φ108mm×thickness 10.5mm

Thermal body φ32mm×thickness 8.5mm

Clear hole φ4.0mm, mass 215g

8. Instrument size: 176×160×108 (MM), mass 2.38kg

X-5 Microscope precision thermostat Golden Terrace

 

1. Input power: AC 220V ±10% 45-60HZ

2. Temperature range: room temperature—450°C

3. Power consumption: 60W

4. The maximum temperature of the outer body of the heating stage: when the heating body is 360°C; when the room temperature is 25°C, it is ≤70°C

5. Accuracy: Measurement accuracy: full range ≤ ± 0.2%

6. System fluctuation: ±1°C

7. Specifications of heating stage: shape φ108mm×thickness 10.5mm

Thermal body φ32mm×thickness 8.5mm

Clear hole φ4.0mm, mass 215g

KER3101-500S For Polarization Microscope 1. Input power: AC 220V ±10% 45-60HZ

2. Temperature range: room temperature—500°C

3. The range of heating/cooling speed can be set: 1-60 seconds/℃ (the heating and cooling are the same as the knob)

4. Temperature rise/fall control: automatic recognition conversion, one-twist setting.

5. The maximum temperature of the outer body of the heating stage: when the heating body is 500°C; when the room temperature is 25°C, it is ≤70°C

6. Accuracy: Measurement accuracy: full range ≤ ± 0.5%

7. System fluctuation: ±1°C

8. Immediate constant temperature response time: ≤0.01 seconds

X-500S Microscope precision thermostat Golden Terrace

 

1. Input power: AC 220V ±10% 45-60HZ

2. Temperature range: room temperature—500°C

3. Power consumption: 60W

4. The maximum temperature of the outer body of the heating stage: when the heating body is 360°C; when the room temperature is 25°C, it is ≤70°C

5. Accuracy: Measurement accuracy: full range ≤ ± 0.2%

6. System fluctuation: ±1°C

7. Specifications of heating stage: shape φ108mm×thickness 10.5mm

Thermal body φ32mm×thickness 8.5mm

Clear hole φ4.0mm, mass 215g

8. Instrument size: 176×160×108 (MM), mass 2.38kg

KER5100 High-precision two-way precision thermostat (hot and cold stage)

 

1. Temperature range of constant temperature table: minus 50°C. (The lowest temperature depends on the temperature of the heat exchange fluid. When the heat exchange flow is at room temperature of 18 °C, it can reach minus 30 °C.

2. Controller input power: AC 220V ±10% 45-60HZ.

3. Working power supply of constant temperature table: DC 0-12V 0-6A automatic adjustment.

4. Accuracy: Measurement accuracy: full range≦±0.2%

5. System fluctuation: ±0.1°C Display scale: 0.1°C

6. Rise/fall speed function: bidirectional linear.

7. The heating/cooling speed range can be set: 1-36 seconds/0.1 ℃, the same button setting, automatic conversion.

8. Immediate constant temperature response time: ≦0.1 seconds.

9. Heating/cooling status judgment: automatic.

10. Heating/cooling crossover out of control zone: ≦±1.5℃.